| Standby Power - 6 V 4 OPzV 200 Data | ||||
| To
view data for entire range, click here: Specifications
: Constant Current : Constant Power |
||||
| Product Specification Data | |||||||||
| Type | Nom V |
C10@ 20°C |
L mm |
W mm |
H mm |
Mass kg |
Acid l |
Cell Arrangement |
Cell Centre |
| 6 V 4 OPzV 200 | 6 | 182 | 273 | 204 | 350 | 43 | - | - | - |
| Constant Current Discharge Data (amps at 20 °C) | ||||||||||||||
| Cell / Bat Type | VpC | 5 Min | 10 Min | 15 Min | 20 Min | 30 Min | 45 Min | 1 Hr | 2 Hr | 3 Hr | 5 Hr | 6 Hr | 8 Hr | 10 Hr |
| 6 V 4 OPzV 200 | 1.65 | 313 | 273 | 240 | - | 179 | - | 114 | 70.3 | 50.9 | 33.8 | 29 | 22.8 | 18.6 |
| 1.70 | 277 | 253 | 223 | - | 173 | - | 114 | 70.3 | 50.9 | 33.8 | 29 | 22.8 | 18.6 | |
| 1.75 | 253 | 227 | 187 | - | 155 | - | 108 | 66.5 | 49.8 | 33.1 | 28.4 | 22.4 | 18.6 | |
| 1.80 | 231 | 201 | 181 | - | 148 | - | 101 | 63.9 | 47.9 | 31.9 | 27.6 | 22 | 18.2 | |
| 1.83 | 205 | 181 | 162 | - | 131 | - | 91.2 | 60 | 45.2 | 30.8 | 26.7 | 21.3 | 17.5 | |
| 1.87 | 177 | 162 | 137 | - | 116 | - | 81.7 | 55.9 | 42.6 | 29.3 | 25.3 | 20.1 | 16.7 | |
| Constant Power Discharge Data (watts at 20°C) | ||||||||
| Cell / Bat Type | VpC | 5 Min | 10 Min | 15 Min | 20 Min | 30 Min | 45 Min | 1 Hr |
| 6 V 4 OPzV 200 | 1.65 | 1575 | 1386 | 1230 | - | 933 | - | 627 |
| 1.70 | 1428 | 1314 | 1170 | - | 918 | - | 627 | |
| 1.75 | 1335 | 1206 | 999 | - | 834 | - | 597 | |
| 1.80 | 1254 | 1098 | 993 | - | 816 | - | 567 | |
| 1.83 | 1131 | 999 | 900 | - | 729 | - | 516 | |
| 1.87 | 999 | 915 | 774 | - | 654 | - | 468 | |
| © First National Battery 2004 |